Pbxsummary
Supportfiles1Aastra BP.TDS
Supportfiles2Aastra BP.TDT
Additionaltasks3Install NetPBX
Requiredtask1Configure the SMDR output
Requiredtask3Install NetPbx
Requiredtask2Configure TIM Plus
ConnectionSerial connection
Additionaltasks1Configure your SMDR
Additionaltasks2Configure TIM Plus

Configuring your SMDR

 

BP firmware R12 or older

If you are using firmware which is older than R12, you need to setup the SMDR output to

Keywordmacro
LabelCIL 3

BP firmware R13+

If you are using firmware R13+, you will need to set the SMDR output to

Keywordmacro
LabelFlexible CIL
and configure the options as below:

Screenshotmacro
Borderfalse
URLhttp://docs.call-logger.com:8090/download/attachments/4817023/aastra_bp_1.png

 </p> <img class="screenshot" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/aastra_bp_1.png" alt="Aastra BP" /> <h2>Configuring TIM Plus</h2> <p>Below

Configuring TIM Plus

Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Aastra BP:</p>

 

 

HTML
<p>These instructions should assist in configuring your Aastra BP to 
work with TIM Plus. If you are not familiar with PBX 
configuration, please contact your system maintainer.</p>

<table class="confluenceTable">
	<tbody>
		<tr>
			<th class="confluenceTh" width=158>Connection information</th>
			<th class="confluenceTh">Description</th>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Connection type</b></td>
			<td class="confluenceTd"><b>Serial Output: </b>
				As the Aastra BP sends SMDR information via a serial connection which is located on BP unit itself. You will need to directly connect a serial cable from the Aastra BP to the PC that NetPBX is installed and 
				running on.
			</td>
		</tr>
		<tr>
			<td class="confluenceTd"><b>Cable configuration</b></td>
			<td class="confluenceTd">Null-modem/Crossover.
			</td>
		</tr>
	</tbody>
</table>

<h2>Configuring your SMDR</h2>

<h4>BP firmware R12 or older</h4>

<p>If you are using firmware which is older than R12, you need to setup the SMDR output to <span class="keyword">CIL3</span>.</p>

<h4>BP firmware R13+</h4>

<p>If you are using firmware R13+, you will need to set the SMDR output to <span class="keyword">Flexible CIL</span> and configure the options as below:</p>

<img class="screenshot" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/aastra_bp_1.png" alt="Aastra BP" />

<h2>Configuring TIM Plus</h2>

<p>Below you will find steps on how to configure TIM Plus to listen for SMDR data from your Aastra BP:</p>

<ol>
	<li>Browse to TIM Plus as normal and login with your credentials.</li>
	<li>Click on the <span class="button no_margin">Directory</span> tab.</li>
	<li>Click on the site configured during the setup wizard and click <span class="button no_margin">Properties</span> or create a new site and click <span class="button no_margin">Properties</span>.</li>
	<img class="screenshot border" src="http://www.tri-line.com/common/img/documentation/tim_plus/pbx/aastra_bp_2.png" alt="Aastra BP" />
	<li>Within the <span class="reference">Site Properties</span> window, select <span class="keyword">Aastra BP</span> from the <span class="reference">PBX model</span> drop-down list.</li>
	<li>In the <span class="reference">Connection method</span> field select <span class="keyword">No connection required</span> from the drop-down list.</li>
	<li>Finally, click on the <span class="button no_margin">Save</span> button.</li>
</ol>