- Press the key.
- Press the key.
- Press . You are now in Programming mode.
- Navigate to Call logging/Remote programming parameters.
- Go to Call logging-parity check and select 1 and then press the key.
- Go to Call logging-even/odd parity and select 1 and then press the key.
- Go to Call logging-baud rate (SMDR) and select 4 and then press the key.
- Go to Call logging-stop bit and select 1 and then press the key.
- Go to Call logging-data length and select 4 and then press the key.
- Got to Call logging-printing selection out/in, select 1 which will give you incoming and outgoing calls.
- Go to Call logging-printing selection local/long distance calls, select 1 which will print all outgoing calls and then press the key.
- Press the key and your settings will be saved.
HTML |
---|
<a id="Install NetPBX><NetPBX"></a> |
Installing NetPBX
The NEC DXE phone system sends SMDR information via a serial connection. To collect the data from the serial port and send it to TIM Plus, you will first need to install the NetPBX software. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Plus><Plus"></a> |
Configuring TIM Plus
Once NetPBX is configured and collecting data, log on to TIM Plus as usual and apply the following settings:
...