- Press the key.
- Press the key.
- Press the the
.Referencemacro Label Programming mode to enter - Navigate to Call logging/Remote programming parameters.
- Go to Call logging-parity check and select 1, then press the key.
- Go to Call logging-even/odd parity and select 1, then press the key.
- Go to Call logging-baud rate (SMDR) and select 4, then press the key.
- Go to Call logging-stop bit and select 1, then press the key.
- Go to Call logging-data length and select 4, then press the key.
- Go to Call logging-printing selection out/in and select 1 for the incoming and outgoing calls.
- Go to Call logging-printing selection local/long distance calls and select 1 to print all outgoing calls, then press the key.
- Press the key to save the settings.
...