Follow the steps below to configure your Avaya BCM to output SMDR data to TIM PlusEnterprise:
- Log in to the BCM Element Manager.
- On the Task Navigation Panel, click the tab.
- Click on .
Click on
.In the Call Detail Recording panel that appears, configure the options as below:
SMDR field Value Format Norstar Report Type All Language English Date Format MM/DD/YY Header Format Line/Station Filter Type All Feature Code F9 Leave as default Minimum Call Duration Leave as default Hospitality Records Leave as default Include DNIS Info Enable Include CLID with call type Enable Include Long CLID Leave as default Use answer supervision Leave as default Display connection character Leave as default Suppress digits after connect Leave as default Maximum digits after connect Leave as default
...
Follow the steps below to configure TIM Enterprise to collect the SMDR data from your Alcatel OmniPCX EnterpriseAvaya BCM:
- Click on the tab.
- Choose the PBX object you want to configure and click Properties.
- A new window will open. In the Avaya BCM 4+ from the Data format list and tick the Keep a local backup of data box, as shown below:
Screenshotmacro Border false URL /download/attachments/3801135/avaya_bcm_3.png tab, select - In the Establish TCP connection to PBX from the Connection method list. tab, select
- In the Host field, enter the IP address of your Avaya BCM.
- In the Port field, enter 4000.
- In the Username field, enter the username of the CDR user you configured in the BCM Unified Manager utility (above)
- In the Password field, enter the password for the CDR user.
- In the Connection script field, select Avaya BCM v4 from the drop-down list.
- Click on the
Screenshotmacro Border false URL /download/attachments/3801135/avaya_bcm_4.png button to apply the changes.
...