- Press the key.
- Press the key.
- Press the the
.Referencemacro Label Programming mode to enter - Navigate to Call logging/Remote programming parameters.
- Go to Call logging - parity Parity check and select 1, then press the key.
- Go to Call logging - evenEven/odd Odd parity and select 1, then press the the key.
- Go to Call logging - baud Baud rate (SMDR) and select 4, then press the key.
- Go to Call logging - stop Stop bit and select 1, then press the key.
- Go to Call logging - data Data length and select 4, then press the key.
- Go to Call logging - printing Printing selection out/in and select 1 for the incoming and outgoing calls.
- Go to Call logging - printing Printing selection local/long distance calls and select 1 to print all outgoing calls, then press the key.
- Press the key to save the settings.
HTML |
---|
<a id="Install NetPBX"></a> |
Installing NetPBX
The NEC DXE phone The Panasonic DBS Series phone system sends SMDR information via a serial connection. To collect the call logging data from the serial port and send it to TIM Plus, you first need to install the NetPBX netpbx software. For setup instructions, click on the link below:
HTML |
---|
<a id="Configure TIM Plus"></a> |
...
Once NetPBX is configured and collecting call logging data, log in to TIM Plus and perform the steps below:
- Click on the tab.
- Choose the site you want to configure and clickclick .
Screenshotmacro Border false URL /download/attachments/4817095/panasonic_dbs_1.png - In the Site Properties window, select Panasonic DBS Series from the PBX model drop-down list.
- In the Connection method field, select No connection required from the drop-down list.
- Click on the button to apply the settings.