Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Follow the steps below to configure your Avaya BCM to output SMDR data to TIM PlusEnterprise:

  1. Log in to the BCM Element Manager.
  2. On the Task Navigation Panel, click the Configuration tab.
  3. Click on Telephony.
  4. Click on Call Detail Recording.

  5. In the Call Detail Recording panel that appears, configure the options as below:

    SMDR fieldValue
    FormatNorstar
    Report TypeAll
    LanguageEnglish
    Date FormatMM/DD/YY
    Header FormatLine/Station
    Filter TypeAll
    Feature Code F9Leave as default
    Minimum Call DurationLeave as default
    Hospitality RecordsLeave as default
    Include DNIS InfoEnable
    Include CLID with call typeEnable
    Include Long CLIDLeave as default
    Use answer supervisionLeave as default
    Display connection characterLeave as default
    Suppress digits after connectLeave as default
    Maximum digits after connectLeave as default
HTML
<a id="Configure a CDR user"></a>

CDR User

To enable TIM Plus Enterprise to connect to your Avaya BCM, you need to create a CDR User under the System option in the BCM Unified Manager configuration utility.

HTML
<a id="Configure TIM Enterprise"></a>

 

Configuring TIM Enterprise

Follow the steps below to configure TIM Enterprise to collect the SMDR data from your Alcatel OmniPCX EnterpriseAvaya BCM:

  1. Click on the Directory tab.
  2. Choose Locate the PBX object you want to configure and click in the Directory, right-click on it and select Properties.
  3. A new window will open. In the General tab, select , displaying the general properties of your PBX object. Select Avaya BCM 4+ from the Data format list and tick the the 
    Keywordmacro
    LabelKeep a local backup of data
    box, as shown below:
    Screenshotmacro
    Borderfalse
    URL/download/attachments/3801135/avaya_bcm_3.png
  4. In Click on the Connection tab , and select Establish TCP connection to PBX from the Connection method list.
  5. In the Host field, enter the IP address of your Avaya BCM.
  6. In the Port field, enter 4000.
  7. In the Username field, enter the username of the CDR user you configured in the BCM Unified Manager utility (above)
  8. In the Password field, enter the password for the CDR user.
  9. In the Connection script field, select Avaya BCM v3v4 from the drop-down list.
  10. Click on the Save button to apply the changes.
    Screenshotmacro
    Borderfalse
    URL/download/attachments/3801135/avaya_bcm_4.png