These instructions help you configure your LG iPECS phone system to work with TIM PlusEnterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.
Pbxsummary | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
|
HTML |
---|
<a id="Configure the SMDR output"></a> |
...
In the Printer Port Selection (PGM 175) window, set Info/On-line SMDR to Telnet 1 to send call logging data to TIM Plus Enterprise over TCP to port 23.
ISDN Attributes (PGM 200)
To enable CLI information in the call records produced by your LG iPECS, you need to set the CLI Print To Serial to ON, as shown below:
Screenshotmacro | ||||
---|---|---|---|---|
|
HTML |
---|
<a id="Configure TIM Enterprise"></a> |
...
- Click on the tab.
- Choose Locate the PBX object you want to configure and click in the Directory, right-click on it and select Properties.
- A new window will open. In the tab, select , displaying the general properties of your PBX object. Select LG iPECS from the Data format list and tick the the
box, as shown below:Keywordmacro Label Keep a local backup of data Screenshotmacro Border false URL /download/attachments/13271191/lg_ipecs_3.png - In Click on the tab , and select Establish TCP connection to PBX from the Connection method list.
- In the Host field, enter the IP address of your LG iPECS.
- In the Port field, enter 23.
- Leave the Username and Password fields blank.
- In the Connection IP script field, select Generic Simple from the drop-down list.
- Click on the
Screenshotmacro Border false URL /download/attachments/13271191/lg_ipecs_ip.png button to apply the settings.