![](/s/en_GB/3145/191/_/images/icons/emoticons/warning.png)
These instructions should assist in configuring your Siemens HiPath 4000 to work with TIM Enterprise. If you are not familiar with PBX configuration, please contact your system maintainer.
Connection information | Description |
---|---|
Connection type | IP |
IP method | TCP/IP connection: The Siemens HiPath 4000 sends SMDR information via TCP/IP on a TCP port. TIM Enterprise will connect to the IP address of Siemens HiPath 4000. |
SMDR configuration | You will need to speak to your system maintainer to enable SMDR output, they will need to tell you the IP address and TCP port to connect to. |
Configuring TIM Enterprise
Below you will find steps on how to configure TIM Enterprise to connect to your Siemens HiPath 4000 to receive SMDR:
- Browse to TIM Enterprise as normal and login with your credentials.
- Click on the tab.
- Go the the point in the Directory where you need to add the PBX Object and add a PBX with the name 'Siemens HiPath 4000'.
- Left-click on it and select .
- From the Siemens HiPath 4000 from the PBX model list. settings tab select
- In the Establish TCP connection to PBX from the Connection method list. tab select
- In the Host field enter in the IP address e.g. 192.168.1.1.
- In the Port field enter in 9000.
- Leave the Username and Password fields blank.
- In the IP script field select Generic Simple.
- Finally, click on the button.
![Siemens HiPath 4000](http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/siemens_hipath_4000_1.png)
![Siemens HiPath 4000](http://www.tri-line.com/common/img/documentation/tim_enterprise/pbx/siemens_hipath_4000_2.png)
Labels: