Skip to end of metadata
Go to start of metadata

These instructions help you configure your Aastra Intelligate/2025/2045/2065 phone system to work with TIM Plus. Contact your system maintainer if you are not familiar with the configuration of your PBX.

Connection Type
  TIM Plus establishes a serial connection with this PBX.

Support Files
  Aastra PC5.TDT
  Aastra PC5.TDS
Required Tasks
  Configure the SMDR output
  Install NetPBX
  Configure TIM Plus

Configuring your SMDR output

The Aastra Intelligate/2025/2045/2065 can output SMDR information in multiple formats. You should always select the PC5 format for use with TIM Plus.

Below are some screenshots to demonstrate how the Aastra Intelligate Series should be configured:

 

Setting the SMDR format to PC5


Setting the SMDR format to TCP/IP


Setting the SMDR format to PC5

The OIP Server has a very basic call logging module. If you intend to install TIM Plus alongside the OIP Server, you need to uninstall the call logging module from the OIP Server suite, otherwise, when configuring your Aastra to output the data to the PC running TIM Plus, the OIP Server will overwrite some required settings.

Installing NetPBX

Install and configure NetPBX

Configuring TIM Plus

Once NetPBX is configured and collecting data, log in to TIM Plus and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the site you want to configure and click Properties.

  3. In the Site Properties window, select Aastra PC5 from the PBX model drop-down list.
  4. In the Connection method field, select No connection required from the drop-down list.
  5. Click on the Save button to apply the changes.

 

Labels: