These instructions help you configure your NEC Aspire phone system to work with TIM Enterprise. Contact your system maintainer if you are not familiar with the configuration of your PBX.

<a id="Configure the SMDR output"></a>

Configuring your SMDR output

Follow the steps below to configure the SMDR output on your NEC Aspire:

  1. Log in to your PC Pro/Web Pro software.
  2. To configure SMDR output by serial port, apply the following settings for each system adapter:

    AdapterProgramming codeValueDescription
    NTCPU - Serial10-21-021NTCPU Hardware Setup - Baud Rate for COM Port. Choose the baud rate from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400
    35-01-011SMDR Options - Output Port Type
    CTA/CTU - Serial15-02-191Multi-Line Telephone Basic Data Setup - CTA/CTU Data Communication Module
    15-02-201Multi-Line Telephone Basic Data Setup - Baud Rate for CTA/CTU port. Choose from the three available options: 0 = 4800, 1 = 9600, and 2 = 38400
    35-01-014SMDR Options - Output Port Type
    35-01-02Extension number that the CTA/CTU adaptor is attached to.SMDR Options - Output Destination Number
  3. Apply the following settings in the programming sections below:

    Programming codeValueDescription
    14-01-061Basic Trunk Data Setup - SMDR Print.
    15-01-031Basic Extension Data Setup - SMDR Print.
    35-01-030SMDR Options - Header Language.
    35-01-040SMDR Options - Omit (Mask) Digits.
    35-01-050SMDR Options - Minimum Number of SMDR Digits.
    35-01-060SMDR Options - Minimum Call Duration.
    35-01-070SMDR Options - Minimum Ringing Time.
    35-01-08DefaultSMDR Options - SMDR Format.
    35-02-010SMDR Output Options - Toll Restricted Call.
    35-02-021SMDR Output Options - PBX Calls.
    35-02-031SMDR Output Options - Display Trunk Name or Numbers.
    35-02-040SMDR Output Options - Daily Summary.
    35-02-050SMDR Output Options - Weekly Summary.
    35-02-060SMDR Output Options - Monthly Summary.
    35-02-081SMDR Output Options - Incoming calls.
    35-02-090SMDR Output Options - Print Name or Numbers.
    35-02-100SMDR Output Options - All Lines Busy (ALB) Output.
    35-02-120SMDR Output Options - DID Table Name Output.
    35-02-131SMDR Output Options - CLI Output when DID to Trunk.
    35-02-141SMDR Output Options - Date.
    35-02-151SMDR Output Options - CLI/DID Number Switching.
    35-02-161SMDR Output Options - Print Trunk Name or Received Dialled Number.
    35-02-170SMDR Output Options - Print Account Code or Caller ID Name.
    35-02-18DefaultSMDR Output Options - Caller ID Name Output Method.
    80-05-011Date Format for SMDR and System Reports.
<a id="Install NetPBX"></a>

Installing NetPBX

Install and configure NetPBX

<a id="Configure TIM Enterprise"></a>

Configuring TIM Enterprise

Once NetPBX is configured and collecting data, log in to TIM Enterprise and perform the following steps:

  1. Click on the Directory tab.
  2. Choose the PBX object you want to configure and click Properties.
  3. A new window will open. In theĀ General tab, select NEC Aspire from the Data format list and tick the Keep a local backup of data box, as shown below:
  4. In theĀ Connection tab, select No connection required from the Connection method list.
  5. Click on the Save button to apply the settings.